Generalaire AC24 User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
The condition indicator gauge will show when media replacement is required. Use Air Cleaner media assembly Part No. 13156.
CARE AND MAINTENANCE
Slide the assembled media frame into the air cleaner
cabinet. Be sure the airflow arrow on the media frame
points toward the furnace blower. The plastic pleat
spacers are always on the downstream side of the
filter media. Attach outer cover.
Turn on electricity and run furnace blower on highest
speed. Calibrate condition indicator, with a small
screwdriver adjust the calibration screw to put the
pointer in the center of the “FILTER IS CLEAN” range.
Install the plastic pleat spacers, being careful to insert
one support finger between each pleat. Press each
end of the pleat spacers down firmly to fully engage
the media frame. Pleat spacers may snag on air
cleaner cabinet if not pressed down below media
frame rail.
Place new media pack (Part No. 13156) onto the media
frame. Slide media pack toward foam gasket. Line up
holes in the cardboard strips with the holes in the
media frame.
Turn off electricity to furnace.
Pull front cover off and
slide media carrier out of air cleaner cabinet.
Place air
cleaner media frame on table with plastic pleat spacers
on top. Loosen pleat spacers by gently lifting at each
end. Carefully remove all pleat spacers. Lift used air
cleaner media out of frame for disposal and clean
media frame.
AIR
FILTER
BLOWER
RETURN
AIR
GAGE
1 2
3 4
5
FILTER
CONDITION
FILTER IS CLEAN
CHANGE FILTER
Page view 1
1 2 3 4

Comments to this Manuals

No comments