READ AND SAVE THESE INSTRUCTIONS
PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before beginning installation. Do not install where
temperatures fall below 32 degrees F or where plenum temperatures exceed 200 degrees F. When wiring into a multi-speed blower circuit see Step 7D.
INSTALLATION: The humidifier may be mounted with the 6" outlet to the right or left by reversing the position of the Bypass Cover. The humidifier may
be mounted on the warm or return air plenum with equal efficiency. See Typical Installations below.
INSTALLER: PLEASE FILL OUT AND MAIL GUARANTEE CARD AFTER INSTALLATION
IS COMPLETE. LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER
HIGH BOY COUNTER-FLOW LOW BOY
RETURN AIR
RETURN AIR
RETURN AIR
WARM AIR
WARM AIR
WARM AIR
WARM AIR
DRAIN
DRAIN
DRAIN
ADDITIONAL MATERIALS THAT MAY BE NESSESARY:
1. 1/4" diameter copper or plastic water
supply tubing (G.F. #747-38 suggested)
2. 5/8" diameter drain tubing (G.F. #1099-16 suggested)
3. 3/4" O.D. drain tube clamp (G.F. #P-163 suggested)
4. 6" diameter galvanized by-pass pipe
5. 6" diameter galvanized elbow
6. 6" diameter galvanized damper
7. 6" diameter collar
8. wire, two-conductor #18 or heavier
(G.F. #727-48 suggested)
9. transformer 120V, 60HZ primary 24V,
10VA or greater secondary (G.F. #727-58 suggested)
10. air pressure switch (G.F. Model #12500 suggested)
11. current sensing relay (G.F. Model #GA50 suggested)
GENERALAire AC SERIES
HIGH EFFICIENCY AIR CLEANER
R
R
Fresh Indoor Air Quality
SL-16
Select location on vertical surface of warm or return air plenum for
mounting humidifier and tape mounting template. Make sure the
template is level. Do not install humidifier or 6" bypass pipe where the
blanked off ends of a cooling coil will restrict air flow to the humidifier.
Extend horizontal centerline from template to the adjacent plenum.
Scribe 6” circle 10” to 15” from side of humidifier, on cabinet centerline.
Start the three initial mounting screws. Mount humidifier cabinet in
level position and tighten screws. Install six additional screws at top
and sides of cabinet.
1
2
CUT TEMPLATE ALONG THIS LINE CUT TEMPLATE ALONG THIS LINE
CENTERLINE
CUT SHEETMETAL ALONG THIS LINE
INITIAL
MOUNTING
HOLE
INITIAL
MOUNTING
HOLE
INITIAL
MOUNTING
HOLE
OPENING CLEARANCE ABOVE THIS LINE
PREFERRED: 2 1/2 INCH.
MINIMUM: 1 1/2 INCH.
3
COPPER
TUBING
PLASTIC
TUBING
Cut 6hole and install connecting collar, 6” elbow and by-pass pipe
(not supplied). USE UNCRIMPED END IN HUMIDIFIER CABINET.
Connect by-pass pipe to collar and humidifier cabinet. Using holes
at top and bottom of humidifier bypass opening, screw by-pass pipe
to humidifier cabinet. Install bypass cover by placing the tab of the
bypass cover marked "TOP" behind the top flange of the humidifier
cabinet, push up on the bottom clip until it clears the opening of the
humidifier cabinet then push in on the bottom of the bypass cover.
NOTE: If furnace is used for summer cooling, install inline
damper in by-pass pipe.
Mount the self tapping saddle valve on either a cold or a hot water pipe. A
side or top mount is best to avoid clogging from pipe sediment. Connect 1/4”
O.D. tubing to the saddle valve. Copper tubing requires a brass compression
nut and brass sleeve. Plastic tubing requires a brass insert inside the tubing,
a plastic sleeve on the outside with a brass compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN
CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT.
INSTALLATION OF THIS SADDLE VALVE MUST MEET OR
EXCEED LOCAL CODES AND ORDINANCES.
4
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - GENERALAire AC SERIES

142 READ AND SAVE THESE INSTRUCTIONSPRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before beginn

Page 2 - PLENUM SURFACE OR DUCT

65SADDLE VALVE INSTALLATION INSTRUCTIONSCopper Pipe 1. Retract piercing pin into valve body by turning handle counterclockwise.2. Screw valve body i

Page 3

WIRE JUMPER7A7C7B7D7(HOT)115v.60CY.ON-OFF SWITCHCOMMON LEADFURNACECHILOGA50CURRENTSENSINGRELAYMULTISPEEDBLOWERMOTORAC LAC NHUMSNSR24V. SOLENOID VALVE7

Page 4 - CARE AND MAINTENANCE

-20 F -29 C° 15%°-10 F -23 C° 20%°0 F -18 C° 25%°+10 F -29 C+20 F - 7 C° 30%°° 35%°+30 F - 1 C° 40%°The operating principle of the humidifier

Page 5 - WARRANTY REGISTRATION

PARTS LIST FOR HUMIDIFIERLIMITED WARRANTYThis humidifier, if properly registered by the return of the warranty registration card to the manufacturer,